Compact Diesel Engine Generator Mounted Transport Carriage 6 3D Model

Not Rated Yet





































! REPORT
NOTE: DIGITAL DOWNLOAD, NOT A PHYSICAL ITEM

Add to Collection

0 Likes
Offered By
specialist modeler : solidworks, autocad, inventor, sketchup, 3dsmax,
License
Extended Use License
This item comes with our Extended Use Licensing. This means that you may use the model for both non-commercial and commercial purposes, in a variety of mediums and applications.
For full license terms, see our 3D Content Licensing Agreement
3D Model Details
| Vendor: | surf3d |
| Published: | Dec 23, 2025 |
| Download Size: | 307.6 MB |
| Game Ready: | – |
| Polygons: | 1,103,498 |
| Vertices: | 811,368 |
| Print Ready: | – |
| 3D Scan: | – |
| Textures: | – |
| Materials: | Yes |
| UV Mapped: | – |
| PBR: | – |
| Rigged: | – |
| Animated: | – |
Statistics
| Favorites: | 0 |
| Likes: | 0 |
| Views: | 1 |
Item Ratings

Not Rated Yet
Compact Diesel Engine Generator Mounted Transport Carriage 6 3D Model
High-quality 3D assets at affordable prices — trusted by designers, engineers, and creators worldwide. Made with care to be versatile, accessible, and ready for your pipeline.
Included File Formats
This model is provided in 14 widely supported formats, ensuring maximum compatibility:
• - FBX (.fbx) – Standard format for most 3D software and pipelines
• - OBJ + MTL (.obj, .mtl) – Wavefront format, widely used and compatible
• - STL (.stl) – Exported mesh geometry; may be suitable for 3D printing with adjustments
• - STEP (.step, .stp) – CAD format using NURBS surfaces
• - IGES (.iges, .igs) – Common format for CAD/CAM and engineering workflows (NURBS)
• - SAT (.sat) – ACIS solid model format (NURBS)
• - DAE (.dae) – Collada format for 3D applications and animations
• - glTF (.glb) – Modern, lightweight format for web, AR, and real-time engines
• - 3DS (.3ds) – Legacy format with broad software support
• - 3ds Max (.max) – Provided for 3ds Max users
• - Blender (.blend) – Provided for Blender users
• - SketchUp (.skp) – Compatible with all SketchUp versions
• - AutoCAD (.dwg) – Suitable for technical and architectural workflows
• - Rhino (.3dm) – Provided for Rhino users
Model Info
• - All files are checked and tested for integrity and correct content
• - Geometry uses real-world scale; model resolution varies depending on the product (high or low poly)
• • - Scene setup and mesh structure may vary depending on model complexity
• - Rendered using Luxion KeyShot
• - Affordable price with professional detailing
Buy with confidence. Quality and compatibility guaranteed.
If you have any questions about the file formats, feel free to send us a message — we're happy to assist you!
Sincerely,
SURF3D
Trusted source for professional and affordable 3D models.
More Information About 3D Model :
**COMPACT DIESEL ENGINE GENERATOR MOUNTED TRANSPORT CARRIAGE DOLLY**
A Compact Diesel Engine Generator Mounted Transport Carriage Dolly, often formally designated as a Mobile Diesel Generating Set Cart or Utility Power Dolly, is a specialized, self-contained apparatus engineered to provide independent electrical power in non-fixed or temporary operating environments. This equipment integrates a robust power generation unit—consisting of a compression-ignition engine and an alternator—onto a durable, maneuverable wheeled frame (dolly or carriage), maximizing portability without compromising operational output or structural integrity.
### Nomenclature and Classification
The apparatus falls within the classification of portable energy solutions, distinct from larger trailer-mounted or fixed-base gensets primarily due to its compact footprint and chassis design optimized for manual or low-speed towing maneuverability across diverse terrains. These units typically service power demands ranging from 5 kVA (kilovolt-amperes) to 30 kVA, fitting the requirements for light industrial, commercial, and emergency backup applications.
### Core Components and Configuration
#### Power Generation Unit (Genset)
The primary mover is typically a compact, industrial-grade four-stroke diesel engine. Diesel propulsion is favored for its high energy density, inherent reliability, superior torque characteristics, and generally lower operational costs relative to gasoline counterparts, especially under sustained load. The engine may be air-cooled or liquid-cooled, depending on the required thermal management and operational duty cycle.
The engine is rigidly coupled to a brushless, synchronous alternator (generator head), designed to produce standard alternating current (AC) power, providing either single-phase (e.g., 120/240V) or three-phase (e.g., 208/480V) output at standard industrial frequencies (50 or 60 Hz).
#### Control and Safety Systems
The unit incorporates a comprehensive control panel featuring instrumentation for monitoring critical operational parameters, including engine speed (RPM), oil pressure, coolant temperature (if liquid-cooled), battery voltage, and electrical output characteristics (voltage, frequency, current load). Integrated protective relays and circuit breakers provide overload protection, while essential engine safety mechanisms include automatic shutdown protocols activated by low oil pressure or high engine temperature. Fuel storage is typically facilitated by an integral, base-mounted fuel tank designed to provide operational autonomy for defined periods (e.g., 6 to 12 hours) at nominal load.
### The Transport Carriage (Dolly) System
The structural foundation is a high-strength, welded steel or aluminum frame engineered to withstand the static and dynamic stresses associated with engine operation and transport. The design incorporates critical features to ensure component longevity and operator safety:
1. **Vibration Isolation:** The engine and alternator assembly is mounted to the frame utilizing specialized elastomeric or spring-based vibration isolation mounts (dampeners). These mounts are essential for absorbing the significant kinetic energy produced by the diesel engine, preventing destructive vibration transference to the frame, control panel electronics, and the supporting ground surface, thus minimizing noise emissions.
2. **Wheeled Chassis:** The "dolly" or "carriage" designation refers to the mobility system, which employs large-diameter, often pneumatic or solid rubber tires. The chassis configuration is optimized for maneuverability, featuring ergonomic handle assemblies or tow bars for manual positioning.
3. **Handling Features:** For larger units, the frame includes designated mechanical handling points, such as center lifting bails (or hooks) for crane deployment and integrated fork pockets for transport via forklift or pallet jack, ensuring secure placement and retrieval.
### Applications
Compact Diesel Engine Generator Mounted Transport Carriage Dollies are crucial assets in scenarios requiring temporary or localized electrical supply where rapid deployment and repositioning are necessary. Primary sectors include:
* **Construction and Civil Engineering:** Supplying power to power tools, lighting rigs, and temporary site offices.
* **Emergency Services and Disaster Relief:** Providing immediate power for lighting, communication systems, and critical medical infrastructure.
* **Remote Field Operations:** Used by utility and telecommunication companies for maintenance, testing, and backup power at off-grid sites.
* **Event Management:** Providing quiet, localized power for small-scale events or sensitive areas where space is limited.
KEYWORDS: Diesel Generator, Mobile Power Unit, Genset Dolly, Transport Carriage, Portable Generator, Compact Power, Compression Ignition, Synchronous Alternator, Power Generation, Wheeled Chassis, Emergency Power, Construction Equipment, Utility Cart, Vibration Damping, kVA Output, Engine Controller, Fuel Efficiency, Site Power, Backup Generator, Maneuverable, Temporary Power, Load Management, Industrial Grade, Four-Stroke Engine, Air-Cooled, Telecommunications Backup, Remote Operation, AC Power Source, Power Cart, Mechanical Handling.
Included File Formats
This model is provided in 14 widely supported formats, ensuring maximum compatibility:
• - FBX (.fbx) – Standard format for most 3D software and pipelines
• - OBJ + MTL (.obj, .mtl) – Wavefront format, widely used and compatible
• - STL (.stl) – Exported mesh geometry; may be suitable for 3D printing with adjustments
• - STEP (.step, .stp) – CAD format using NURBS surfaces
• - IGES (.iges, .igs) – Common format for CAD/CAM and engineering workflows (NURBS)
• - SAT (.sat) – ACIS solid model format (NURBS)
• - DAE (.dae) – Collada format for 3D applications and animations
• - glTF (.glb) – Modern, lightweight format for web, AR, and real-time engines
• - 3DS (.3ds) – Legacy format with broad software support
• - 3ds Max (.max) – Provided for 3ds Max users
• - Blender (.blend) – Provided for Blender users
• - SketchUp (.skp) – Compatible with all SketchUp versions
• - AutoCAD (.dwg) – Suitable for technical and architectural workflows
• - Rhino (.3dm) – Provided for Rhino users
Model Info
• - All files are checked and tested for integrity and correct content
• - Geometry uses real-world scale; model resolution varies depending on the product (high or low poly)
• • - Scene setup and mesh structure may vary depending on model complexity
• - Rendered using Luxion KeyShot
• - Affordable price with professional detailing
Buy with confidence. Quality and compatibility guaranteed.
If you have any questions about the file formats, feel free to send us a message — we're happy to assist you!
Sincerely,
SURF3D
Trusted source for professional and affordable 3D models.
More Information About 3D Model :
**COMPACT DIESEL ENGINE GENERATOR MOUNTED TRANSPORT CARRIAGE DOLLY**
A Compact Diesel Engine Generator Mounted Transport Carriage Dolly, often formally designated as a Mobile Diesel Generating Set Cart or Utility Power Dolly, is a specialized, self-contained apparatus engineered to provide independent electrical power in non-fixed or temporary operating environments. This equipment integrates a robust power generation unit—consisting of a compression-ignition engine and an alternator—onto a durable, maneuverable wheeled frame (dolly or carriage), maximizing portability without compromising operational output or structural integrity.
### Nomenclature and Classification
The apparatus falls within the classification of portable energy solutions, distinct from larger trailer-mounted or fixed-base gensets primarily due to its compact footprint and chassis design optimized for manual or low-speed towing maneuverability across diverse terrains. These units typically service power demands ranging from 5 kVA (kilovolt-amperes) to 30 kVA, fitting the requirements for light industrial, commercial, and emergency backup applications.
### Core Components and Configuration
#### Power Generation Unit (Genset)
The primary mover is typically a compact, industrial-grade four-stroke diesel engine. Diesel propulsion is favored for its high energy density, inherent reliability, superior torque characteristics, and generally lower operational costs relative to gasoline counterparts, especially under sustained load. The engine may be air-cooled or liquid-cooled, depending on the required thermal management and operational duty cycle.
The engine is rigidly coupled to a brushless, synchronous alternator (generator head), designed to produce standard alternating current (AC) power, providing either single-phase (e.g., 120/240V) or three-phase (e.g., 208/480V) output at standard industrial frequencies (50 or 60 Hz).
#### Control and Safety Systems
The unit incorporates a comprehensive control panel featuring instrumentation for monitoring critical operational parameters, including engine speed (RPM), oil pressure, coolant temperature (if liquid-cooled), battery voltage, and electrical output characteristics (voltage, frequency, current load). Integrated protective relays and circuit breakers provide overload protection, while essential engine safety mechanisms include automatic shutdown protocols activated by low oil pressure or high engine temperature. Fuel storage is typically facilitated by an integral, base-mounted fuel tank designed to provide operational autonomy for defined periods (e.g., 6 to 12 hours) at nominal load.
### The Transport Carriage (Dolly) System
The structural foundation is a high-strength, welded steel or aluminum frame engineered to withstand the static and dynamic stresses associated with engine operation and transport. The design incorporates critical features to ensure component longevity and operator safety:
1. **Vibration Isolation:** The engine and alternator assembly is mounted to the frame utilizing specialized elastomeric or spring-based vibration isolation mounts (dampeners). These mounts are essential for absorbing the significant kinetic energy produced by the diesel engine, preventing destructive vibration transference to the frame, control panel electronics, and the supporting ground surface, thus minimizing noise emissions.
2. **Wheeled Chassis:** The "dolly" or "carriage" designation refers to the mobility system, which employs large-diameter, often pneumatic or solid rubber tires. The chassis configuration is optimized for maneuverability, featuring ergonomic handle assemblies or tow bars for manual positioning.
3. **Handling Features:** For larger units, the frame includes designated mechanical handling points, such as center lifting bails (or hooks) for crane deployment and integrated fork pockets for transport via forklift or pallet jack, ensuring secure placement and retrieval.
### Applications
Compact Diesel Engine Generator Mounted Transport Carriage Dollies are crucial assets in scenarios requiring temporary or localized electrical supply where rapid deployment and repositioning are necessary. Primary sectors include:
* **Construction and Civil Engineering:** Supplying power to power tools, lighting rigs, and temporary site offices.
* **Emergency Services and Disaster Relief:** Providing immediate power for lighting, communication systems, and critical medical infrastructure.
* **Remote Field Operations:** Used by utility and telecommunication companies for maintenance, testing, and backup power at off-grid sites.
* **Event Management:** Providing quiet, localized power for small-scale events or sensitive areas where space is limited.
KEYWORDS: Diesel Generator, Mobile Power Unit, Genset Dolly, Transport Carriage, Portable Generator, Compact Power, Compression Ignition, Synchronous Alternator, Power Generation, Wheeled Chassis, Emergency Power, Construction Equipment, Utility Cart, Vibration Damping, kVA Output, Engine Controller, Fuel Efficiency, Site Power, Backup Generator, Maneuverable, Temporary Power, Load Management, Industrial Grade, Four-Stroke Engine, Air-Cooled, Telecommunications Backup, Remote Operation, AC Power Source, Power Cart, Mechanical Handling.

















