Mobile Power Pallet Diesel Engine Generator Set Genset Cart 3D Model

Not Rated Yet



















! REPORT
NOTE: DIGITAL DOWNLOAD, NOT A PHYSICAL ITEM

Add to Collection

0 Likes
Offered By
specialist modeler : solidworks, autocad, inventor, sketchup, 3dsmax,
License
Extended Use License
This item comes with our Extended Use Licensing. This means that you may use the model for both non-commercial and commercial purposes, in a variety of mediums and applications.
For full license terms, see our 3D Content Licensing Agreement
3D Model Details
| Vendor: | surf3d |
| Published: | Dec 23, 2025 |
| Download Size: | 297.1 MB |
| Game Ready: | – |
| Polygons: | 1,089,289 |
| Vertices: | 794,078 |
| Print Ready: | – |
| 3D Scan: | – |
| Textures: | – |
| Materials: | Yes |
| UV Mapped: | – |
| PBR: | – |
| Rigged: | – |
| Animated: | – |
Statistics
| Favorites: | 0 |
| Likes: | 0 |
| Views: | 1 |
Item Ratings

Not Rated Yet
Mobile Power Pallet Diesel Engine Generator Set Genset Cart 3D Model
High-quality 3D assets at affordable prices — trusted by designers, engineers, and creators worldwide. Made with care to be versatile, accessible, and ready for your pipeline.
Included File Formats
This model is provided in 14 widely supported formats, ensuring maximum compatibility:
• - FBX (.fbx) – Standard format for most 3D software and pipelines
• - OBJ + MTL (.obj, .mtl) – Wavefront format, widely used and compatible
• - STL (.stl) – Exported mesh geometry; may be suitable for 3D printing with adjustments
• - STEP (.step, .stp) – CAD format using NURBS surfaces
• - IGES (.iges, .igs) – Common format for CAD/CAM and engineering workflows (NURBS)
• - SAT (.sat) – ACIS solid model format (NURBS)
• - DAE (.dae) – Collada format for 3D applications and animations
• - glTF (.glb) – Modern, lightweight format for web, AR, and real-time engines
• - 3DS (.3ds) – Legacy format with broad software support
• - 3ds Max (.max) – Provided for 3ds Max users
• - Blender (.blend) – Provided for Blender users
• - SketchUp (.skp) – Compatible with all SketchUp versions
• - AutoCAD (.dwg) – Suitable for technical and architectural workflows
• - Rhino (.3dm) – Provided for Rhino users
Model Info
• - All files are checked and tested for integrity and correct content
• - Geometry uses real-world scale; model resolution varies depending on the product (high or low poly)
• • - Scene setup and mesh structure may vary depending on model complexity
• - Rendered using Luxion KeyShot
• - Affordable price with professional detailing
Buy with confidence. Quality and compatibility guaranteed.
If you have any questions about the file formats, feel free to send us a message — we're happy to assist you!
Sincerely,
SURF3D
Trusted source for professional and affordable 3D models.
More Information About 3D Model :
The Mobile Power Pallet Diesel Engine Generator Set, frequently abbreviated as a Genset Trolley or Mobile Power Unit (MPU), is a specialized category of electrical power generation equipment characterized by its robust, self-contained structure and inherent rapid-deployment mobility. This apparatus serves as a critical source of temporary, primary, or emergency electrical power, typically utilized in environments lacking fixed utility infrastructure or during instances of utility power failure.
### Configuration and Nomenclature
The designation "Mobile Power Pallet" refers specifically to the mechanical integration of the core generation components onto a heavy-duty, skid-based or palletized chassis, which is further supplemented by a wheeled assembly (the "trolley") for manual or low-speed towing and repositioning.
**Core Components:**
1. **Diesel Engine:** A compression-ignition internal combustion engine serves as the prime mover. Diesel engines are selected for their high thermal efficiency, durability, torque characteristics, and ability to handle varying loads, making them suitable for continuous industrial operation.
2. **Generator (Alternator):** The engine is mechanically coupled, either directly or via a flexible coupling, to a synchronous alternator. This component converts mechanical rotational energy into usable alternating current (AC) electricity at specified voltage and frequency standards (e.g., 50 Hz or 60 Hz).
3. **Frame and Enclosure:** The entire assembly is mounted on a rigid, often anti-vibration isolated, steel base frame (the pallet). For environmental protection, noise mitigation, and safety, the unit is encased within a weather-resistant, sound-attenuated canopy. Integrated lifting points (e.g., forklift pockets or central crane hooks) are standard for logistical deployment.
4. **Trolley Mechanism:** The defining feature of the "Trolley" designation is the incorporation of heavy-duty, pneumatic or solid-rubber wheels and an axle system. This configuration enhances localized mobility, allowing the genset to be maneuvered manually or towed short distances without the necessity of a dedicated trailer or specialized lifting equipment.
### Operational Characteristics
Mobile Power Pallet gensets are designed for robust performance in demanding operational environments. Power output typically ranges from small-scale units (5 kVA to 50 kVA) suitable for site tools and lights, up to medium-industrial sizes (100 kVA to 300 kVA) capable of powering significant operational loads.
**Key Design Features:**
* **Fuel Autonomy:** Units incorporate integrated, often double-walled, fuel tanks designed to provide extended operational run times (e.g., 8 to 24 hours) under standard load conditions, minimizing immediate refueling requirements.
* **Control System:** A centralized Electronic Control Unit (ECU) manages engine parameters, monitors generator output (voltage regulation, frequency), and provides diagnostic information. Safety shutdowns are mandated for low oil pressure, high coolant temperature, and electrical faults.
* **Voltage Regulation:** Modern sets employ sophisticated Automatic Voltage Regulators (AVR) to maintain stable output voltage, critical for sensitive electronic equipment often powered in field environments.
### Applications and Utility
The flexibility and self-contained nature of the Mobile Power Pallet configuration make it highly valuable across multiple sectors where speed of deployment and location independence are essential.
1. **Construction and Infrastructure:** Providing temporary site power for tools, lighting, and accommodation units before permanent utility connections are established.
2. **Emergency and Disaster Relief:** Serving as primary power sources for command centers, field hospitals, temporary communication infrastructure, and critical relief efforts following natural disasters.
3. **Utility and Telecom Maintenance:** Supplying continuous power (bridging power) during scheduled maintenance or unplanned outages of fixed infrastructure, ensuring continuity of service.
4. **Military and Field Operations:** Utilized for rapid deployment in tactical situations where reliable, movable power generation is required for equipment and remote bases.
5. **Event Management:** Supplying reliable electrical power for temporary stages, lighting, and vendor facilities at outdoor festivals or events.
KEYWORDS: Diesel Generator, Mobile Power Unit, Genset Trolley, Power Pallet, Emergency Power, Portable Generator, Standby Power, Skid-Mounted, Alternator, Compression Ignition, Temporary Power, Remote Power, Rapid Deployment, Construction Power, Sound Attenuation, Heavy-Duty Chassis, Field Operations, kVA Rating, AC Generation, Industrial Power, Synchronous Alternator, Fuel Autonomy, Engine-Generator Set, Trailerized Genset, Utility Support, Telecom Power, Disaster Relief, Integrated Fuel Tank, Electronic Control Unit, Wheeled Generator.
Included File Formats
This model is provided in 14 widely supported formats, ensuring maximum compatibility:
• - FBX (.fbx) – Standard format for most 3D software and pipelines
• - OBJ + MTL (.obj, .mtl) – Wavefront format, widely used and compatible
• - STL (.stl) – Exported mesh geometry; may be suitable for 3D printing with adjustments
• - STEP (.step, .stp) – CAD format using NURBS surfaces
• - IGES (.iges, .igs) – Common format for CAD/CAM and engineering workflows (NURBS)
• - SAT (.sat) – ACIS solid model format (NURBS)
• - DAE (.dae) – Collada format for 3D applications and animations
• - glTF (.glb) – Modern, lightweight format for web, AR, and real-time engines
• - 3DS (.3ds) – Legacy format with broad software support
• - 3ds Max (.max) – Provided for 3ds Max users
• - Blender (.blend) – Provided for Blender users
• - SketchUp (.skp) – Compatible with all SketchUp versions
• - AutoCAD (.dwg) – Suitable for technical and architectural workflows
• - Rhino (.3dm) – Provided for Rhino users
Model Info
• - All files are checked and tested for integrity and correct content
• - Geometry uses real-world scale; model resolution varies depending on the product (high or low poly)
• • - Scene setup and mesh structure may vary depending on model complexity
• - Rendered using Luxion KeyShot
• - Affordable price with professional detailing
Buy with confidence. Quality and compatibility guaranteed.
If you have any questions about the file formats, feel free to send us a message — we're happy to assist you!
Sincerely,
SURF3D
Trusted source for professional and affordable 3D models.
More Information About 3D Model :
The Mobile Power Pallet Diesel Engine Generator Set, frequently abbreviated as a Genset Trolley or Mobile Power Unit (MPU), is a specialized category of electrical power generation equipment characterized by its robust, self-contained structure and inherent rapid-deployment mobility. This apparatus serves as a critical source of temporary, primary, or emergency electrical power, typically utilized in environments lacking fixed utility infrastructure or during instances of utility power failure.
### Configuration and Nomenclature
The designation "Mobile Power Pallet" refers specifically to the mechanical integration of the core generation components onto a heavy-duty, skid-based or palletized chassis, which is further supplemented by a wheeled assembly (the "trolley") for manual or low-speed towing and repositioning.
**Core Components:**
1. **Diesel Engine:** A compression-ignition internal combustion engine serves as the prime mover. Diesel engines are selected for their high thermal efficiency, durability, torque characteristics, and ability to handle varying loads, making them suitable for continuous industrial operation.
2. **Generator (Alternator):** The engine is mechanically coupled, either directly or via a flexible coupling, to a synchronous alternator. This component converts mechanical rotational energy into usable alternating current (AC) electricity at specified voltage and frequency standards (e.g., 50 Hz or 60 Hz).
3. **Frame and Enclosure:** The entire assembly is mounted on a rigid, often anti-vibration isolated, steel base frame (the pallet). For environmental protection, noise mitigation, and safety, the unit is encased within a weather-resistant, sound-attenuated canopy. Integrated lifting points (e.g., forklift pockets or central crane hooks) are standard for logistical deployment.
4. **Trolley Mechanism:** The defining feature of the "Trolley" designation is the incorporation of heavy-duty, pneumatic or solid-rubber wheels and an axle system. This configuration enhances localized mobility, allowing the genset to be maneuvered manually or towed short distances without the necessity of a dedicated trailer or specialized lifting equipment.
### Operational Characteristics
Mobile Power Pallet gensets are designed for robust performance in demanding operational environments. Power output typically ranges from small-scale units (5 kVA to 50 kVA) suitable for site tools and lights, up to medium-industrial sizes (100 kVA to 300 kVA) capable of powering significant operational loads.
**Key Design Features:**
* **Fuel Autonomy:** Units incorporate integrated, often double-walled, fuel tanks designed to provide extended operational run times (e.g., 8 to 24 hours) under standard load conditions, minimizing immediate refueling requirements.
* **Control System:** A centralized Electronic Control Unit (ECU) manages engine parameters, monitors generator output (voltage regulation, frequency), and provides diagnostic information. Safety shutdowns are mandated for low oil pressure, high coolant temperature, and electrical faults.
* **Voltage Regulation:** Modern sets employ sophisticated Automatic Voltage Regulators (AVR) to maintain stable output voltage, critical for sensitive electronic equipment often powered in field environments.
### Applications and Utility
The flexibility and self-contained nature of the Mobile Power Pallet configuration make it highly valuable across multiple sectors where speed of deployment and location independence are essential.
1. **Construction and Infrastructure:** Providing temporary site power for tools, lighting, and accommodation units before permanent utility connections are established.
2. **Emergency and Disaster Relief:** Serving as primary power sources for command centers, field hospitals, temporary communication infrastructure, and critical relief efforts following natural disasters.
3. **Utility and Telecom Maintenance:** Supplying continuous power (bridging power) during scheduled maintenance or unplanned outages of fixed infrastructure, ensuring continuity of service.
4. **Military and Field Operations:** Utilized for rapid deployment in tactical situations where reliable, movable power generation is required for equipment and remote bases.
5. **Event Management:** Supplying reliable electrical power for temporary stages, lighting, and vendor facilities at outdoor festivals or events.
KEYWORDS: Diesel Generator, Mobile Power Unit, Genset Trolley, Power Pallet, Emergency Power, Portable Generator, Standby Power, Skid-Mounted, Alternator, Compression Ignition, Temporary Power, Remote Power, Rapid Deployment, Construction Power, Sound Attenuation, Heavy-Duty Chassis, Field Operations, kVA Rating, AC Generation, Industrial Power, Synchronous Alternator, Fuel Autonomy, Engine-Generator Set, Trailerized Genset, Utility Support, Telecom Power, Disaster Relief, Integrated Fuel Tank, Electronic Control Unit, Wheeled Generator.

















